Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine, OIL,GAS & Petrochemical Cables 

British Standard Fire resistant Shipwiring cables to BS 7917

Unarmoured 1 KV Power

Unarmoured 1 KV Power

Used widely on ships, oil rigs, gas platforms and many other places where small bending radii are required and fire resistance to IEC60331 is vital, these cables provide circuit integrity to maintain essential emergency services in the event of a fire.

Colour Codes

a) Colour coded
1 Core Red or black
2 Core Red, black
3 Core Red, yellow, blue
4 Core Red, yellow, blue, black
5 Core and above Sequentially numbered
b) Number coded -  most popular for stock items

Technical Information

Voltage rating 0.6/1kV
Conductors BS6360 class 2 or class 5
(Class 5 is generally manufactured to order)
Temperature rating +90°C maximum conductor temperature
Static temperature rating -30°C to +90°C
Bending radius (static) ≤ 10mm² 3 x cable O/D
    10mm² to 25mm² 4 x cable O/D
>  25mm² 4 x cable O/D
Flame retardant IEC60332 part 3A, BS4066 part 3A
Fire resistant IEC60331 (3 hours @ +750°C)

Technical Data

Nominal area
of conductor
mm
Diameter over
outer sheath
min-max mm
 Single-core cables
 1   5.1 - 6.3 
 1.5   5.4 - 6.6 
 2.5   5.8 - 7.0 
 4   6.7 - 8.0 
 6   7.2 - 8.5 
 10   8.1 - 9.5 
 16   9.3 - 10.7 
 25   11.5 - 13.2 
 35   12.3 - 14.1 
 50   14.1 - 15.9 
 70   15.8 - 17.8 
 95   18.1 - 20.2 
 120   20.0 - 22.4 
 150   22.0 - 24.6 
 185   24.4 - 27.0 
 240   27.5 - 30.3 
 300   30.4 - 33.6 
 400   34.1 - 37.5 
 500   38.0 - 41.5 
 630   41.6 - 45.6 
 Two-core cables
 1   8.3 - 9.6 
 1.5   9.0 - 10.4 
 2.5   9.8 - 11.4 
 4   11.8 - 13.5 
 6   12.9 - 14.6 
 10   14.9 - 16.8 
 16   17.1 - 19.1 
 25   21.2 - 23.7 
 35   23.1 - 25.7 
 50   26.5 - 29.2 
 70   30.3 - 33.5 
 95   34.9 - 38.2 
 120   38.4 - 42.2 
 150   42.5 - 46.5 
 185   47.1 - 51.3 
 240   53.5 - 58.2 
 300   59.3 - 64.3 
Nominal area
of conductor
mm
Diameter over
outer sheath
min-max mm
 Three-core cables
 1   9.0 - 10.4 
 1.5   9.6 - 11.0 
 2.5   10.4 - 12.1 
 4   12.6 - 14.3 
 6   13.8 - 15.5 
 10   15.9 - 17.8 
 16   18.2 - 20.3 
 25   22.9 - 25.4 
 35   24.9 - 27.6 
 50   28.5 - 31.3 
 70   32.7 - 35.9 
 95   37.5 - 41.0 
 120   41.3 - 45.3 
 150   45.8 - 49.9 
 185   50.9 - 55.5 
 240   57.5 - 62.4 
 300   64.0 - 69.4 
 Four-core cables
 1   9.8 - 11.4 
 1.5   10.5 - 12.1 
 2.5   11.4 - 13.1 
 4   13.8 - 15.6 
 6   15.3 - 17.3 
 10   17.7 - 19.7 
 16   20.3 - 22.8 
 25   25.5 - 28.1 
 35   27.7 - 30.5 
 50   31.8 - 35.0 
 70   36.3 - 39.7 
 95   41.7 - 45.7 
 120   46.2 - 50.3 
 150   51.1 - 55.7 
 185   56.8 - 61.6 
 240   64.3 - 69.8 
 300   71.5 - 77.6 
  Five-core cables and above
 5x1.5   11.4 - 13.1 
 7x1.5   12.6 - 14.4 
 12x1.5   16.8 - 18.8 
 19x1.5   19.9 - 22.4 
 27x1.5   24.3 - 26.9 
 37x1.5   27.4 - 30.4 
 5x2.5   12.7 - 14.4 
 7x2.5   13.9 - 15.6 
 12x2.5   18.7 - 20.8 
 19x2.5   22.1 - 24.7